This is historical information of device classes implemented in PyStateComposer device server.
Use this link to find the valid information.
Development status:
Released
Information status: New
Contact:
Class Description
- When a new Device is added the composer subscribes to its State changes.
- If it is not able to subscribe to events, then a polling thread is started. relays on PyTango_utils package to provide DynamicAttributes and DynamicStates. Either StatePolicy or DynamicStates property can be used to compose the State. StatePolicy uses the same format than Soleil`s composer, the default policy is generated the first time the composer is launched
Families: Calculation
Key words:
Language: Python
Contact:
Class interface
Attributes:
Name | Description |
---|---|
VersionNumberScalar: DevString | — |
StatesListSpectrum: DevString | — |
DevicesListSpectrum: DevString | — |
DevStatesSpectrum: DevString | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
AddDeviceInput: DevString Output: DevVoid |
None. |
RemoveDeviceInput: DevString Output: DevVoid |
None. |
UpdateStatePolicyInput: DevVoid Output: DevVoid |
Updates the way State is computed |
Pipes:
Properties:
Name | Description |
---|---|
DynamicAttributesString[]Type | Attributes and formulas to create for this device.This Tango Attributes will be generated dynamically using this syntax: AllPressures=DevVarDoubleArray([XAttr(dev+`/Pressure`) or 0 for dev in DEVICES]) |
DynamicStatesString[]Type | This property will allow to declare new States dinamically based on dynamic attributes changes: FAULT=any([s==FAULT for s in STATES]) ON=1 |
DynamicStatusString[]Type | Each line generated by this property code will be added to status |
CheckDependenciesDevBoolean | This property manages if dependencies between attributes are used to check readability. |
PollingCycleDevLong | Default period for polling all device states. |
UseEventsString[]Type | This property allows to enable/disable events management. |
DevicesListString[]Type | A list of device names, wildcards like domain/family/ * are allowed.If this property is not initialized DeviceNameList is read instead. |
IgnoreListString[]Type | A list of device names, wildcards like domain/family/ * are allowed.The devices in this list will not be used to compose the state. |
SubComposersString[]Type | A list of composer device names from which devices/states lists will be imported. |
StatePolicyString[]Type | A list of States and its priority. this property is not used if DynamicStates has been initialized. |
SortListsDevBoolean | A property to control whether DEVICES/STATES lists will be sorted or not |
LogLevelDevString | This property selects the log level (DEBUG/INFO/WARNING/ERROR) |
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:20 Apr 2017, 1:07 p.m.