This is historical information of device classes implemented in Prosilica device server.

Use this link to find the valid information.

Development status: Released
Information status: New

Contact:



Class Description


Families: Acquisition

Key words: 2D

Language: Cpp

License:

Contact:

Class interface


Attributes:

Name Description
ExposureScalar: DevDouble
RoiSpectrum: DevLong
BinningSpectrum: DevShort
TriggerScalar: DevShort
WidthScalar: DevLong
HeightScalar: DevLong
DepthScalar: DevShort
FramesScalar: DevLong
ImageImage: DevUChar
ImageCounterScalar: DevLong
ImageFormatScalar: DevString
JpegImageSpectrum: DevUChar
JpegQualityScalar: DevShort
FileFormatScalar: DevString
FileParamsSpectrum: DevString
FullWidthScalar: DevLong
FullHeightScalar: DevLong
JpegCompressionScalar: DevBoolean
BayerImageSpectrum: DevUChar
GainScalar: DevLong
ShortImageImage: DevShort

Commands:

Name Description
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
LiveInput: DevVoid
Output: DevVoid
Start camera in live acquisition mode.
StopInput: DevVoid
Output: DevVoid
stop the live acquisition mode
ResetInput: DevVoid
Output: DevVoid
reset ROI, binning and scaling to the full image values
WriteFileInput: DevVoid
Output: DevVoid
write image to file in the selected format, use the file parameters to generate file name
TGradientInput: DevShort
Output: DevLong
This command makes an estimation about the focalization of the camera. The calculation is done on the current image.
StartInput: DevVoid
Output: DevVoid
Take a single image frame and do the necessary calculation on the acquired image. After the command is executed the image and the results can be read.
SnapInput: DevVoid
Output: DevVoid
Trigger the camera by software

Pipes:

Properties:

Name Description
IpDevString Identifies Prosilica camera
Init_binningDevShort Initial binning (both for X and Y)
Fixed_frame_rateDevLong Frames per second
Jumbo_framesDevBoolean Define if it is posible to use Jumbo Frames.

22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:20 Apr 2017, 1:04 p.m.