This is historical information of device classes implemented in Medipix device server.
Use this link to find the valid information.
Development status:
Released
Information status: New
Contact:
Class Description
Families: Acquisition
Key words: 2D
Platform: All Platforms
Language: Cpp
Contact:
Hardware
Manufacturer: none
Bus: Ethernet
Class interface
Attributes:
Name | Description |
---|---|
DeviceIdScalar: DevLong | — |
NumberOfChipsScalar: DevLong | — |
NumberOfRowsScalar: DevLong | — |
ExposureTimeScalar: DevDouble | — |
NumberOfFramesScalar: DevLong | — |
DirectoryScalar: DevString | — |
FileNameScalar: DevString | — |
ChipBoardIDScalar: DevString | — |
InterfaceNameScalar: DevString | — |
AcquisitionTypeScalar: DevUShort | — |
AcquisitionTypesScalar: DevString | — |
MaskBitFileAsciiScalar: DevString | — |
TestBitFileAsciiScalar: DevString | — |
LowTHSFileAsciiScalar: DevString | — |
HighTHSFileAsciiScalar: DevString | — |
WriteFilesScalar: DevBoolean | — |
AcquisitionModeScalar: DevLong | — |
PolarityScalar: DevBoolean | — |
BiasVoltageScalar: DevDouble | — |
SaveBinaryScalar: DevBoolean | — |
AppendScalar: DevBoolean | — |
FrameDataTypeScalar: DevLong | — |
RepeatScalar: DevUShort | — |
DelayScalar: DevDouble | — |
MedipixTypeScalar: DevString | — |
DACValuesAsStringScalar: DevString | — |
FlipHorizontalScalar: DevBoolean | — |
FlipVerticalScalar: DevBoolean | — |
RotateScalar: DevDouble | — |
DACNamesSpectrum: DevString | — |
DACValuesSpectrum: DevUShort | — |
DACValuesAnalogSpectrum: DevDouble | — |
InterfaceSpecificInfosSpectrum: DevString | — |
AcquisitionModesSpectrum: DevString | — |
Commands:
Name | Description |
---|---|
SetDACValueInput: DevString Output: DevDouble |
Sets a DAC value. The input argument must have the form . |
StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
GetDACValueInput: DevString Output: DevUShort |
None. |
LoadBinaryPixelsCfgInput: DevString Output: DevVoid |
None. |
LoadHighThresholdsInput: DevString Output: DevVoid |
None. |
LoadLowThresholdsInput: DevString Output: DevVoid |
None. |
LoadMaskBitsInput: DevString Output: DevVoid |
None. |
LoadTestBitsInput: DevString Output: DevVoid |
None. |
PerformAcquisitionInput: DevVoid Output: DevVoid |
None. |
PerformFrameAcquisitionInput: DevVoid Output: DevVoid |
None. |
StartTriggerInput: DevVoid Output: DevVoid |
None. |
StopTriggerInput: DevVoid Output: DevVoid |
None. |
PerformIntegralAcquisitionInput: DevVoid Output: DevVoid |
None. |
ResetPixelConfigurationInput: DevVoid Output: DevVoid |
None. |
SetDACsToDefaultInput: DevVoid Output: DevVoid |
None. |
AbortInput: DevVoid Output: DevVoid |
None. |
SaveConfigInput: DevVoid Output: DevVoid |
None. |
Pipes:
Properties:
Name | Description |
---|---|
StorageDevString | Storage type (FILE_STORE, or TANGO_STORE)\nTANGO_STORE must be given like this `TANGO_STORE:some/tango/device` |
ConfigDirectoryDevString | — |
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:20 Apr 2017, 1:04 p.m.