This is historical information of device classes implemented in ImgGrabber device server.
Use this link to find the valid information.
Development status:
Released
Information status: New
Contact:
Class Description
Families: Acquisition
Key words: 2D
Language: Cpp
Contact:
Class interface
Attributes:
Name | Description |
---|---|
CurrentlySavingMovieScalar: DevBoolean | — |
MovieRemainingTimeScalar: DevString | — |
ImageImage: DevUShort | — |
Commands:
Name | Description |
---|---|
ResetROIInput: DevVoid Output: DevVoid |
None. |
StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
OpenInput: DevVoid Output: DevVoid |
None. |
CloseInput: DevVoid Output: DevVoid |
None. |
StartInput: DevVoid Output: DevVoid |
None. |
StopInput: DevVoid Output: DevVoid |
None. |
StartSaveMovieInput: DevVarDoubleStringArray Output: DevVoid |
saves a movie in the directory specified in the MoviePath property, and with the format specified as MovieFormat. |
StopSaveMovieInput: DevVoid Output: DevVoid |
immediately stops the movie saving |
SnapInput: DevVoid Output: DevVoid |
None. |
SetROIInput: DevVarLongArray Output: DevVoid |
None. |
GetROIInput: DevVoid Output: DevVarLongArray |
None. |
SaveSettingsInput: DevVoid Output: DevVoid |
save the current acquisition parameters to the device Properties |
GetPluginInfoInput: DevVoid Output: DevString |
Retrieves information about the grabber plugin used |
ResetCameraInput: DevVoid Output: DevVoid |
None. |
Pipes:
Properties:
Name | Description |
---|---|
PluginLocationDevString | the full path to the ImgGrabber plugin |
MoviePathDevString | the path where the movie/images are recorded |
MovieFormatDevString | the format of the saved files : JPG, PNG, TIF, PGM, BMP, DIB, RAS |
AutoStartDevBoolean | automatically start grabbing at init |
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:20 Apr 2017, 1:03 p.m.