Development status:
    Released,
            Release: Release_1_3
        
    
    Information status: Updated
    
        
    
    
    
    Repository:
    
    
        http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Motion/EH2tthP10
    
    
    
    
    Contact:
    
        
    
Class Description
Virtual motor to make the large flightpath in EH2 to a 2theta motion around the sample.
Families: Motion
Key words:
Platform: Unix Like
Language: Python
License: GPL
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
| Name | Description | 
|---|---|
| PositionScalar: DevDouble | — | 
| UnitLimitMaxScalar: DevDouble | — | 
| UnitLimitMinScalar: DevDouble | — | 
| PositionSimScalar: DevDouble | — | 
| ResultSimSpectrum: DevString | — | 
Commands:
| Name | Description | 
|---|---|
| StateInput: DevVoid Output: State Device state  | 
                        
                            This command gets the device state (stored in its device_state data member) and returns it to the caller. | 
| StatusInput: DevVoid Output: ConstDevString Device status  | 
                        
                            This command gets the device status (stored in its device_status data member) and returns it to the caller. | 
| StopMoveInput: DevVoid Output: DevVoid  | 
                        
                            — | 
| CalibrateInput: DevVoid Output: DevVoid  | 
                        
                            Not implemented | 
Pipes:
Properties:
| Name | Description | 
|---|---|
| r0DevDouble | distance [mm] from sample to the center of rotation of det-table | 
| s0DevDouble | calculation constant | 
| TiltDegDevDouble | tilt angle [deg] between standard and detector coordinate systems | 
| TiltOffsetDevDouble | Offset [deg] | 
| tsamyDeviceNameDevString | Name of the tango device for the tsamy motor | 
| dety1DeviceNameDevString | Name of the tango device for the dety1 motor | 
| detxDeviceNameDevString | Name of the tango device for the detx motor | 
| detrzDeviceNameDevString | Name of the tango device for the detrz motor | 
| fpyDeviceNameDevString | Name of the tango device for the fpy motor | 
Please log in to comment.
Generated
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.