This is historical information of device classes implemented in CryoConTempCtrl device server.

Use this link to find the valid information.

Development status: Released
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Temperature/CryoConTempCtrl
Contact:



Class Description


Class for controlling the Temperature Controller from Cryogenic Control Systems (CryoCon).

Families: Instrumentation

Key words:

Platform: Unix Like

Language: Cpp

License:

Contact:

Hardware


Manufacturer: Cryogenics Control Systems

Product:

32 and 32B

Bus: GPIB

Class interface


Attributes:

Name Description
TempChannelAScalar: DevDouble
TempChannelBScalar: DevDouble
SourceLoop1Scalar: DevString
SourceLoop2Scalar: DevString
SetTempLoop1Scalar: DevDouble Sets and queries the control loop setpoint
SetTempLoop2Scalar: DevDouble Sets and queries the control loop setpoint
RateLoop1Scalar: DevDouble Sets and queries the ramp rate used by the control loop when performing a temperature ramp.
RateLoop2Scalar: DevDouble Sets and queries the ramp rate used by the control loop when performing a temperature ramp.
OutputPowerScalar: DevDouble Current ouptut power of either control loop, as a percentage of the full power scale. The output current is calculated as: CurrentFullScale*sqrt(value/100.)
LoadResistanceHeaterScalar: DevLong Sets or queries the load resistance setting of the primary heater (loop 1). Selections are: 25 for a 25 Ohm load and a 25W maximum output power and 50 for a 50 Ohm load and a 50W maximum output power.
ControlScalar: DevString By writing anything activate enabled control loops. Read current control status.
TypeLoop1Scalar: DevString Loop control type: Off, PID, Man, Table or RampP
TypeLoop2Scalar: DevString Loop control type: Off, PID, Man, Table or RampP

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StopControlLoopsInput: DevVoid
Output: DevVoid
Disengage all control loops

Pipes:

Properties:

Name Description
GpibDeviceDevString Name of the GpibDeviceServer Tango Server to connect to

23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:23 Feb 2017, 11:35 a.m.