.
Development status:
Released,
Release: release_1_2_3
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/PowerSupply/SY2527Crate
Contact:
Class Description
- This device controls the high voltage power supply boards fixed in the SY2527 crate.
- the hadware is manufactured by the "CAEN "company. The used communication protocole is TCP/IP. On device can be seen as 1 HV power supply (PS) system consisted of severals PS boards. Each Board is consisted of 12 Channels (PS board types : A1733; A1833A )
Families: PowerSupply
Key words:
Language: Cpp
Contact:
Class interface
Attributes:
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
GetVoltageOnChannelInput: DevVarUShortArray Output: DevDouble |
None. |
GetMeasVoltageOnChannelInput: DevVarUShortArray Output: DevDouble |
None. |
SetVoltageOnChannelInput: DevVarDoubleArray Output: DevVoid |
None. |
SetVoltageOnAllChannelsInput: DevDouble Output: DevVoid |
None. |
PowerOnOverAllChannelsInput: DevVoid Output: DevVoid |
None. |
PowerOffOverAllChannelsInput: DevVoid Output: DevVoid |
None. |
PowerOnChannelInput: DevVarUShortArray Output: DevVoid |
None. |
PowerOffChannelInput: DevVarUShortArray Output: DevVoid |
None. |
GetChannelStatusInput: DevVarUShortArray Output: DevUShort |
None. |
SetDefaultVoltageOnAllChannelsInput: DevVoid Output: DevVoid |
set Default Voltage On All Channels defined in properties |
Pipes:
Properties:
Name | Description |
---|---|
HostDevString | SY2527 IP adress |
HvPowerSupplyNameDevString | an HV power supply name is consisted of severals boards, each one locked in different slots |
SlotListShort[]Type | this list contains the used slots in the HV Power Supply |
DefaultVoltagesListString[]Type | each element of the list is a default voltage configuration. One configuration is consists of 3 fields according to the following pattern: SlotNumer; ChannelNumber;DefaultValue; don`t forget the ` ; ` character at the end of string |
RampVoltageDevDouble | ramp up & down voltagaes are specified by assigning this property |
Please log in to comment.
Generated
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:23 Feb 2017, 11:06 a.m.