This is historical information of device classes implemented in BronkhorstMassFlow device server.
Use this link to find the valid information.
Development status:
Released
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/MeasureInstruments/BronkhorstMassFlow
Contact:
Class Description
Class for interfacing the Bronkhosrt Mass Flow devices
Families: Instrumentation
Key words:
Platform: Unix Like
Language: Cpp
Contact:
Hardware
Manufacturer: Bronkhorst
Product:
MassFlow
Bus: USB
Class interface
Attributes:
Name | Description |
---|---|
SetPointScalar: DevDouble | Set point |
CurrentScalar: DevDouble | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
Pipes:
Properties:
Name | Description |
---|---|
NodeNbDevLong | Node number (from 1) |
CtrlDeviceDevString | Name of the tango controller device |
Updated:
The device class has been updated.
You are looking at this version now.
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.