This is historical information of device classes implemented in OmsMaxVIO device server.
Use this link to find the valid information.
Development status:
New development
Information status: Updated
Contact:
Class Description
ADC/DAC channels from Oms MaxV cards
Families: InputOutput
Key words:
Platform: Unix Like
Language: Cpp
License: GPL
Contact:
Hardware
Manufacturer: Oms
Product:
MaxV
Bus: VME
Class interface
Attributes:
Name | Description |
---|---|
ADC1Scalar: DevDouble | — |
ADC2Scalar: DevDouble | — |
ADC3Scalar: DevDouble | — |
ADC4Scalar: DevDouble | — |
ADC5Scalar: DevDouble | — |
ADC6Scalar: DevDouble | — |
DAC1Scalar: DevDouble | — |
DAC2Scalar: DevDouble | — |
DAC1ZeroOffsetScalar: DevDouble | — |
DAC2ZeroOffsetScalar: DevDouble | — |
ADC1ZeroOffsetScalar: DevDouble | — |
ADC2ZeroOffsetScalar: DevDouble | — |
ADC3ZeroOffsetScalar: DevDouble | — |
ADC4ZeroOffsetScalar: DevDouble | — |
ADC5ZeroOffsetScalar: DevDouble | — |
ADC6ZeroOffsetScalar: DevDouble | — |
ADC1NbReadoutsScalar: DevLong | Number of readouts for computing the middle value. |
ADC2NbReadoutsScalar: DevLong | Number of readouts for computing the middle value. |
ADC3NbReadoutsScalar: DevLong | Number of readouts for computing the middle value. |
ADC4NbReadoutsScalar: DevLong | Number of readouts for computing the middle value. |
ADC5NbReadoutsScalar: DevLong | Number of readouts for computing the middle value. |
ADC6NbReadoutsScalar: DevLong | Number of readouts for computing the middle value. |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
Pipes:
Properties:
Name | Description |
---|---|
BaseDevLong | vme base address |
13 Nov 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2